Power Distribution Units (PDU)
Server Technology Inc.
Power, Cooling and Environmental Monitoring
D
./Power Distribution;Power Distribution Units (PDU)/17638
Index1.Support and Supplies//Power Protection//Power Strip
SERVER TECHNOLOGY PR29135V2-215877.eps
Blade servers and high-density computing power requirements continue to increase
within the data center creating heat proliferation and more challenges for managing
the IT environment. To maintain their competitive advantage, data center managers
need solutions such as Sentry Switch POPS (Per Outlet Power Sensing) units that
monitor, track and manage servers and IT equipment and the equipment cabinet
infrastructure that houses them.
Sentry Switched POPS PDUs combine all the features and functions of a switched PDU
with the ability to provide power monitoring per an individual outlet/device.
• The Sentry CDU Family meets the UL 60950-1 requirement for branch
circuit protection
• Exclusive true RMS current monitoring is critical to preventing overloads in
high-density computing environments; LED digital displays on the CDU enclosure
report the input current of each phase or branch circuit for simple
load balancing
• The Switched CDU supports two external 10 ft. (3 m) probes. Each of these
probes measure both temperature and humidity. Receive SNMP-based alerts or
e-mail notifications when conditions exceed defined thresholds
• The Switched CDU family has the capability to daisy chain units together; the
Expansion Module provides the ability to link two power circuits under one
IP address
• Remote configuration and management of outlets. Reboot a single- or
dual-power server with one command. Receive SNMP-based alerts and e-mail
alerts when power or environmental conditions exceed thresholds. Assign users
specific access rights to designated outlets or groups.
• Sentry Switched POPS PDUs combine all the features and functions of a
Switched PDU with the ability to provide power monitoring per an individual
outlet/device. Power information per individual outlet includes: current load (A),
voltage (V), power (kW), apparent power (VA), crest factor, and power factor
SWITCHED POPS CDU, PER OUTLET POWER SENSING, 0U
POPS Switched Power Distribution Units
Anixter No. Vendor No. Description
426842 CWG-16V2A313A1 12 x IEC C13, 4 x IEC C19, 208 V 20 A with IEC
C20 inlet (bottom entry), 2 x temp/humid
capable, with retractable fuses (power cord
sold separately)
426843 CWG-16V2C313A1 12 x IEC C13, 4 x IEC C19, 208 V 30 A with
NEMA L6-30P connector and cord (bottom
cord entry), 3 m (10 ft.), 2 x temp/humid
capable, with retractable fuses
426844 CWG-24V2A311A1 18 x IEC C13, 6 x IEC C19, 3 x LED amp meters,
208 V 20 A with C 60320 C20 inlet,
bottom/front entry, 2 x temp/humid capable,
with retractable fuses
426845 CWG-24V2C311A1 18 x IEC C13, 6 x IEC C19, 3 x LED amp meters,
208 V 30 A with NEMA L6-30P connector and
cord, bottom/front entry, 3 m (10 ft.) cord, 2 x
temp/humid capable, with retractable fuses
426846 CWG-24VDD311A1 18 x IEC C13, 6 x IEC C19, 3 x LED amp meters,
208 V 3-phase DELTA, 20 A with NEMA
L15-20P connector and cord, 10 ft. (3 m),
front entry, 2 x temp/humid capable, with
retractable fuses
426847 CWG-24VDE311A1 18 x IEC C13, 6 x IEC C19, 3 x LED amp meters,
208 V 3-phase DELTA, 30 A with NEMA
L15-30P connector and cord, 10 ft. (3 m),
front entry, 2 x temp/humid capable, with
retractable fuses
426848 CWG-24VYL311A1 18 x IEC C13, 6 x IEC C19, 3 x LED amp meters,
208 V 3-phase WYE, 20 A with NEMA L21-20P
connector and cord, 10 ft. (3 m), front entry,
2 x temp/humid capable, with
retractable fuses
426849 CWG-24VYM311A1 18 x IEC C13, 6 x IEC C19, 3 x LED amp meters,
208 V 3-phase WYE, 30 A with NEMA L21-30P
connector and cord, 10 ft. (3 m), front entry,
2 x temp/humid capable, with
retractable fuses
426850 CWG-24V5Z411A1 18 x IEC C13, 6 x IEC C19, 3 x LED amp meters,
240/415 V 3-phase 30 A with NEMA L22-30P
connector and cord, bottom/front cord entry,
3 m (10 ft.) cord, circuit breakers, 2 x
temp/humid capable